PCS-13156 CORROSION INHIBITIVE INDUSTRIAL PRIMER

VOC AS SUPPLIED:
Less than or equal to 3.5 lbs./gallon
Less than or equal 420 grams/liter

COLOR: Red Oxide, White, Gray, and Black

SOLIDS CONTENT:
50% + 2% by Volume

NUMBER OF COMPONENTS: One

SUGGESTED FILM THICKNESS: 1½-2½ mils DFT

THEORETICAL COVERAGE:
800 sq. ft. per mil per gallon

THINNING: None Required

APPLICATION: Brush, Roller, or Spray

APPLICATION TEMPERATURE:
45°F to 120°F

DRY TIME:
At 77oF, 50% relative humidity:
Dust free: 15-30 minutes
To recoat: 2 hours

FORCE DRY: 10 minutes at 180oF

SERVICE TEMPERATURE:
175°F for continuous service
200°F intermittent service

PACKAGING: 5-gallon pails and 55-gallon drums

SHELF LIFE: 6 months minimum in unopened containers when stored between 40oF and 120oF

PCS-13156
CORROSION INHIBITIVE
INDUSTRIAL PRIMER

DESCRIPTION: PCS-13156  is a rust-inhibitive, general-purpose primer for both air-dry and force-cure applications.  The product contains non-toxic, corrosion-inhibitive pigments and is free of heavy metals.

USES:  As an economical primer for fabricated steel, tank exteriors, rolling stock, metal roofs, building siding, etc., PCS-13156 may be top coated with a variety of finishes.

SURFACE PREPARATION:  All surfaces should be free of oil, grease, or other contaminants.  Abrasive blasting is the preferred method of surface preparation; however, loose rust and other interference materials can be removed by power-tool or hand-tool cleaning.

MIXING:  Stir thoroughly before use.

THINNING:  Thinning is generally not required for brush, roller, or spray application.

CLEAN UP:  Clean up immediately after use with R75.

CAUTIONS:  Flammable mixture.  Contains solvents.   Keep away from heat, sparks, and flame.  Use only with adequate ventilation.  AVOID PROLONGED BREATHING OF VAPORS.  AVOID PROLONGED OR REPEATED CONTACT WITH SKIN.  Keep containers closed when not in use.  If used in confined areas, observe the following precautions to prevent hazards of fire or explosions or damage to health: (1) circulate adequate fresh air continuously during application and drying; (2) use fresh air masks and explosion-proof equipment; (3) prohibit all flames, sparks, welding, and smoking near area.

If swallowed, do not induce vomiting.  Call a physician immediately.  For eye contact, flush with lots of water.  In case of skin contact, wash thoroughly with soap and water.

See material safety data sheets for full precautions prior to use.

 


PCS-13156 is intended for INDUSTRIAL USE ONLY.