PCS-504 Acrylic Urethane Finish

COLOR: Standard colors. Special colors available on request.

VOLUME SOLIDS: 57% + 3%; slightly less for deep colors.

VOC AS SUPPLIED: < 3.45 lbs/gallon

THEORETICAL COVERAGE: 915 sq. ft. per mil per gallon

NUMBER OF COMPONENTS: Two

MIXING RATIO: 4 volumes Base to 1 volume Hardener

INDUCTION PERIOD: Not required.

POT LIFE: 4 hours at 77oF

APPLICATION: Roll, brush, or spray

SUGGESTED FILM THICKNESS:
2 - 3 mils DFT

APPLICATION TEMPERATURE: 50oF to 120oF

DRY TIME: To touch, 4 hours; to handle, 8 hours. To recoat, 8 hours at 77oF

SERVICE TEMPERATURE: 200oF

PACKAGING: 5 gallon kits

SHELF LIFE: Minimum of 12 months in unopened containers.
DO NOT STORE ABOVE 90oF.


PCS-504
ACRYLIC URETHANE FINISH

DESCRIPTION:  PCS-504 finish is a VOC compliant, two component, aliphatic acrylic urethane, with good color and gloss retention designed to be used as a finish coat on steel, concrete and masonry surfaces in conjunction with various Permite Primers.  PCS-504 may be applied by brush, roller or spray over properly prepared surfaces and is compatible with most existing coatings.  Pressure washing may also provide suitable surface preparation depending upon job conditions.  PCS-504 cures to a hard, tough, abrasion resistant film.

USES:  Especially suited as a general maintenance coating for pulp and paper mills, chemical plants, power plants, tank farms, water and sewage treatment facilities, mining operations and marine applications.

NOT RECOMMENDED FOR:  Immersion service or for splash and spillage service in strong solvents or concentrated acids and alkalis.

SURFACE PREPARATION:  STEEL:  Remove all oil and grease by solvent cleaning in accordance with SSPC-SP1 and/or proprietary degreaser.  Minimal recommended surface preparation is hand or power tool cleaning per SSPC-SP2 or SP3 followed by recommended spot priming.  CONCRETE:  Remove laitance, surface hardeners or curing compounds by abrasive blasting or other means.  Concrete must be cured 28 days prior to coating application.

PRIMERS:  STEEL:  PCS-800 Epoxy Primer, PCS-9043 Type II Primer.
CONCRETE:  PCS-803 Primer.

MIXING:  Mix four volumes of PCS-504 Finish Base to one volume of PCS-504 Finish Hardener.  It is not necessary to mix the entire kit at one time, but due to the moisture sensitivity of the hardener component, it is recommended that the entire kit be used as quickly as possible.  Partially filled containers should be closed tightly.

APPLICATION:   Flush all equipment thoroughly with Reducer R117 or R132 before use. AIRLESS:  Minimum of 30:1 Pump ratio, .017 tip with 3/8" I.D. fluid line.   Adjust fluid pressure for proper atomization.  Higher ratio pump and/or larger diameter lines may be required when more than 50 ft. of material line is required.  Shield long lines from direct sunlight in hot weather.  CONVENTIONAL SPRAY:  DeVilbiss MBC or JGA gun with 78 to 765 air cap, E fluid tip and needle.  Use a pressure pot with separate atomizing air and fluid pressure regulators; 50-70 PSI atomizing air and 10-15 PSI pot pressure.  For most applications, 1 coat at 2-3 mils dry film thickness, is sufficient.

CLEAN UP: Clean up immediately after use with urethane grade solvent. Do not allow material to set up in paint lines or equipment.

CAUTIONS: Flammable mixture. Contains solvents and isocyanates. Individuals with lung or breathing problems or prior reaction to isocyanates must NOT BE EXPOSED to VAPOR or SPRAY MIST. Keep away from heat, sparks, and flame. Use only with adequate ventilation. AVOID PROLONGED BREATHING OF VAPORS. AVOID PROLONGED OR REPEATED CONTACT WITH SKIN. Keep containers closed when not in use. If used in confined areas, observe the following precautions to prevent hazards of fire or explosions or damage to health: (1) circulate adequate fresh air continuously during application and drying; (2) use fresh air masks and explosion-proof equipment; (3) prohibit all flames, sparks, welding, and smoking near area. If swallowed, do not induce vomiting. Call a physician immediately. For eye contact, flush with lots of water. In case of skin contact, wash thoroughly with soap and water.

See material safety data sheets for full precautions prior to use.

PCS-504 is intended for INDUSTRIAL USE ONLY.